http://www.greenpower.lk/logotyper/bill_logo_13.png
Patric Torle
info@tradgardsteknik.se
0431-222 90
0431-222 70
Greenpower inc - leading provider and manufacturer of agricultural equipment in Scandinavia
Helsingborgsvägen 578
ÄNGELHOLM
262 96
SWEDEN

GREENPOWER Perkins Diesel Power generator 350kVA 280kW Soundproof canopy Manual starting  




greenpower

Greenpower Equipped with a water-cooled Perkins diesel engine. Supplied with stable framework and Green Power electrical panel, voltmeter, frequency meter, ammeter, hour meter, starter key and indicator panel for oil, battery charge and low fuel level.

Specification

  • Prime running power (PRP) 300kVA, 240kW
  • Emergency stand by power (ESP) 330kVA, 264 kW
  • 400/230 V @ 50 Hz 1500 rpm
  • High quality and reliable 6-cylinder Perkins diesel engine
  • Easily operated control panel
  • Brushless permanent magnetized generator IP23 with optional electronic AVR
  • Fuel tank 250 liters with leak protection

» Click Here to view the Engine Datasheet

» Click here to see Datasheet

Technical Data 
Generator Engine  Perkins 2206A-E13TAG2
Type 4 cycle, water-cooled, diesel engine
Compression Ratio 16.3:1
No of Cylinders 6
Cylinders Arrangement In-line
Displacement 12.5 Liters
Bore x Stroke 130 x 157 mm
Prime running power (PRP) 350 kVA/280 kW
Emergency stand by power (ESP) 385 kVA/308 kW
Speed 1500 rpm
Governor Electronic
Fuel consumption 54 liter/hour
Rated current 630 Amps
Rated voltage 400V/230V
Landuse Type of Unit Low Noise, Automation Type
Weight 4120 Kg
Dimension (LxBxH) 4300 x 1750 x 2350 mm
Rotation Anti-clockwise
Fuel tank 400liter with leakage protectoin
Frequency 50Hz
Motor power 409/305 (hp/kW)
Standard tank capacity 400 l
Sound level 69dB (A)
Frequency 50Hz
 
 
General Specification for silent Generator :
  • Modular Design
  • Anti Corrosion powder coated
  • Insulated with acoustic foam lining
  • Central lifting ring, exhaust pipe can be removed, which is easy to transport
  • Lockable doors with key
  • Protective mesh for rotating parts
  • Exterior emergency stop push button
  • Thermally insulated engine exhaust system
  • Doors fitted on each side
  • Panel observing window
  • Access to the radiator fill or cap
  • Color is optional
  • Fuel gauge or lube drain valve is optional
  • Normal or super soundproof canopy is optional
  • Base frame fuel tank or profile fuel tank is optional
  • The muffler fixed position depend on the output power of the Gen-set 

Silent Generator set Canopy :

  • Specially treated steel sheet
  • Stainless steel locks
  • Control panel viewing window for monitoring the status of the generator set
  • Good ventilation system and anti-heat radiation saturation
  • Effective anti-vibration devices to ensure generator driven steadily
  • Super silent materials inside to ensure the noise lower than 68 dB 7 meters away
  • Emergency stop button mounted outside
  • Side lockable door easy for maintenance and installation
  • Lube oil and cooling water drain pipe to the exterior of the canopy
  • Fuel tank built with level indicator
 Standard equipment  Other configurations
  • Air inlet system
  • Automatic fuse magnetothermal
  • Control system
  • Cooling system
  • Fly wheel and flywheel housing
  • Emergency stop button
  • Fuel system
  •  Safety device in the engine for:
    • high water temperature
    • low oil pressure
    • low fuel level 
    • battery charging error
  • Models with different voltage
  • 60 Hz version
   
 Accessories
 
    • Mobile drive wheel
    • Type-approved trailer 
    • Autostart
    • Automatic power switch ATS
    • Automatic power switch and phase-out
    • Blink-free feedback
    • Parallel operation
    • Fuse type
    • Ground fault switch 
    • Extraction point with power transformer input point
    • Radiostatic protection VDE 0875 curve N
    • Electronic speed control
    • Oil heater
    • Engine heater
    • Oil pump
    • Automatic tanker from external tank
    • Protective frame with lift hook 
    • Container unit 
    • Alternator voltage / frequency generator
    • Fuel tank deployment
    • Fuel level 
    • Alarm on all internet connection.
    • GSM alarm monitoring
    • Capable soundproofing 70dB down to 55dB
    • Remote control
    • Environmental Class STAGE III
    • Disconnect 1-phase or 3-phase, respectively
    • UPS system battery backup 1-phase and 3-phase
    Standard Genset Specifications
     
    Engine
    • Perkins heavy duty diesel engine
    • 8 cylinder equipped with Water cooling
    • Mechanical governor control system
    • Replaceable wet type cylinder liners
    • Replaceable fuel filter, oil filter and dry element air filter
    • Cooling radiator and fan
    • Fuel connection hoses and manual sump oil drain valve
    • Exhaust silencer
    • Maintenance free battery including rack and cables
    • Jacket water heater (as option)
    • Perkins Engine Manual
      Alternator
      • Brushless, single bearing system
      • Insulation class H with circuit breaker protection
      • Standard degree of protection IP 23
      • Self-exciting and self-regulating
      • Main line circuit breaker
      • Close voltage regulation

      Greenpower AB reserves the right to make any errors or changes in specifications. © Copyright / Greenpower AB.

        • GREENPOWER Perkins Diesel Power generator 350kVA 280kW Soundproof canopy Manual starting
          Art. nr.
          GP350PS
          GREENPOWER Perkins Diesel Power generator 350kVA 280kW Soundproof canopy Manual starting
          Write down the required equipment for quotation :
        For more information contact us at
        0431-222 90
          Contact   Print